University of Bayreuth logoRDSpace@UBT - repository logo
  • English
  • Deutsch
  • Log In
    New user? Click here to register. Have you forgotten your password?
  • Communities & Collections
  • All of RDSpace@UBT
  1. Home
  2. Browse by Author / Creator

Browsing by Author / Creator "Bifano, Luca"

Now showing 1 - 5 of 5
Results Per Page
Sort Options
  • No Thumbnail Available
    ItemOpen Access
    In-situ monitoring of used-sand regeneration in foundries by impedance spectroscopy
    (University of Bayreuth, 2022-09-06) Bifano, Luca; Weider, Marco; Fischerauer, Alice; Wolf, Gotthard; Fischerauer, Gerhard
    MUT 1 to MUT 4 data contains the measured raw impedance data recorded by Agilent E4980A LCR meter in a frequency range from 20 Hz to 1 MHz. The measuring cells used are a cylindrical plate capacitor with plate spacing 4 cm and plate diameter 13 cm and a cylinder capacitor with an electrode spacing of 1 cm and an electrode height of 10 cm (name: laboratory data). MTP 0 to 5 data contains the measured raw impedance data of used-sand regenerated in a used-sand regenerator recorded by Agilent E4980A LCR meter in a frequency range from 20 Hz to 1 MHz (name: field data). The measurements were performed at laboratory conditions. A tabstop is used as delimiter between the columns in all txt-files. In addition, the measurement logs are stored as pdf files, so that the filling quantities of the individual measurements can also be traced. Finally, a matlab code listing is presented that describes the matlab programs used to evaluate the presented data (name: code listing). A description of the data can be found in the article "In-situ monitoring of used-sand regeneration in foundries by impedance spectroscopy".
  • No Thumbnail Available
    ItemOpen Access
    Raw impedance data for microplastic detection
    (University of Bayreuth, 2022-03-30) Meiler, Valentin; Pfeiffer, Jens; Bifano, Luca; Kandlbinder-Paret, Christoph; Fischerauer, Gerhard
    MUT-Microplastic data contains the measured raw impedance data recorded by Agilent E4980A LCR meter in a frequency range from 20 Hz to 2 MHz for the static measurement and the frequency point 2 MHz for the dynamic measurement. The measuring cell used in the static setup is a cylindrical capacitor with electrode spacing 0.6 cm and electrode height 10 cm. The sensor principle for the dynamic setup is based on a parallel plate capacitor. The measurements were performed at laboratory conditions. A tabstop is used as delimiter between the columns in all txt-files.
  • No Thumbnail Available
    ItemOpen Access
    Raw impedance data for MUT 1 to 3
    (University of Bayreuth, 2021-01-21) Bifano, Luca; Fischerauer, Alice; Liedtke, Alfred; Fischerauer, Gerhard
    MUT 1 to MUT 3 data contains the measured raw impedance data recorded by Agilent E4980A LCR meter in a frequency range from 20 Hz to 1 MHz. The measuring cell used is a cylindrical plate capacitor with plate spacing 4 cm and plate diameter 13 cm. The measurements were performed at laboratory conditions. A tabstop is used as delimiter between the columns in all txt-files.
  • No Thumbnail Available
    ItemOpen Access
    Raw impedance data for MUT 1 to 6 and evaluation data for SVMs
    (University of Bayreuth, 2022-01-11) Bifano, Luca; Fischerauer, Alice; Fischerauer, Gerhard
    MUT 1 to MUT 6 data contains the measured raw impedance data recorded by Agilent E4980A LCR meter in a frequency range from 20 Hz to 1 MHz. The measuring cell used is a cylindrical plate capacitor with plate spacing 4 cm and plate diameter 13 cm. The measurements were performed at laboratory conditions. A tabstop is used as delimiter between the columns in all txt-files. In addition, the measurement logs are stored as pdf files, so that the filling quantities of the individual measurements can also be traced. In addition, the values extracted from the raw data that were used to determine the bar charts are stored in an Excel file. Finally, two MATLAB data files are stored, with which the SVMs was trained and tested.
  • No Thumbnail Available
    ItemOpen Access
    Raw impedance data for MUT MoNiCon and evaluation data for LSTM
    (University of Bayreuth, 2022-04-22) Ma, Xiaohu; Bifano, Luca; Fischerauer, Gerhard
    MUT-MoNiCon data contains the measured raw impedance data recorded by Agilent E4980A LCR meter in a frequency range from 20 Hz to 1 MHz (the data only from 20 Hz to 5 kHz is used). The measuring cell used is a parallel-plate capacitor with plate spacing 1 cm and plate diameter 13 cm. The measurements were performed at laboratory conditions. A tabstop is used as delimiter between the columns in all txt-files. In addition, the measurement logs are stored as pdf files, so that the filling quantities of the individual measurements can also be traced. Finally, two MATLAB data files are stored, with which the LSTMRNN was trained and tested.

University of Bayreuth logo is powered by copyright © 2002-2025 LYRASIS


  • Cookie settings
  • End User Agreement
  • Send Feedback
  • Privacy policy
  • Accessibility
  • Legal notice
  • House rules
  • Contacts