ECT data, impedance data and temperature data presented in “Non-invasive temperature monitoring in fixed-bed reactors by electrical capacitance tomography"

datacite.resourcetypeDataset
dc.contributor.authorWeiss, Michael
dc.contributor.authorFischerauer, Alice
dc.contributor.authorJess, Andreas
dc.contributor.authorFischerauer, Gerhard
dc.date.accessioned2024-06-03T06:19:45Z
dc.date.available2024-06-03T06:19:45Z
dc.date.issued2024
dc.description.abstractThe stored ZIP-file contains following three folders: ECT_data: contains the ECT data of the experiments shown in the paper. For each measurement the reference capacitances for the low and high calibration of the ECT measuring system, the recorded raw capacitances, the reconstructed normalized pixel permittivities as well as the corresponding time vector are provided for the different materials. In case of the catalyst FCDS_LQ3 also the calculated pixel temperatures are provided. The averaging over time as done in the paper has not been performed with the data provided here. Electrical_impedance_data: contains the recorded impedance data used for investigating the permittivity-temperature relationship of the different materials examined. Thermocouple_data: contains the temperature measurement data recorded with a thermocouple centered in the fixed-bed at the height of the measuring electrodes. This data was used for comparison with the pixel temperatures calculated from the ECT for the catalyst FCDS-LQ3
dc.identifier.doi10.57880/rdspace-ubt-24
dc.identifier.urihttps://doi.org/10.57880/rdspace-ubt-24
dc.identifier.urihttps://rdspace.uni-bayreuth.de/handle/rdspace-ubt/24
dc.language.isoen
dc.publisherUniversity of Bayreuth
dc.rights.licenseCreative Commons Attribution 4.0 Internationalen
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectElectrical Capacitance Tomography (ECT)
dc.subjectFixed-bed Reactor
dc.subjectTemperature Profile
dc.subjectNon-invasive
dc.subjectTemperatur Monitoring
dc.titleECT data, impedance data and temperature data presented in “Non-invasive temperature monitoring in fixed-bed reactors by electrical capacitance tomography"
dc.typeDataset

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
ECT_TM_in_FBR.zip
Size:
155.74 MB
Format:
Unknown data format
Description:
The stored ZIP-file contains following three folders: ECT_data: contains the ECT data of the experiments shown in the paper. For each measurement the reference capacitances for the low and high calibration of the ECT measuring system, the recorded raw capacitances, the reconstructed normalized pixel permittivities as well as the corresponding time vector are provided for the different materials. In case of the catalyst FCDS_LQ3 also the calculated pixel temperatures are provided. The averaging over time as done in the paper has not been performed with the data provided here. Electrical_impedance_data: contains the recorded impedance data used for investigating the permittivity-temperature relationship of the different materials examined. Thermocouple_data: contains the temperature measurement data recorded with a thermocouple centered in the fixed-bed at the height of the measuring electrodes. This data was used for comparison with the pixel temperatures calculated from the ECT for the catalyst FCDS-LQ3